-- Dell Remote Access Controller (RAC) Management Information Base
-- Copyright (c) 2008  Dell Inc
--
-- Last Changed Revision: 13
-- Last Changed Date: 2011-08-30 12:25:06 -0500 (Tue, 30 Aug 2011)
-- Text Last Updated: 2011-08-30 12:25:06 -0500 (Tue, 30 Aug 2011)
--

DELL-RAC-MIB DEFINITIONS ::= BEGIN
     
IMPORTS
	enterprises, TimeTicks
		FROM RFC1155-SMI
	OBJECT-TYPE
		FROM RFC-1212
	TRAP-TYPE
		FROM RFC-1215
	DisplayString
		FROM SNMPv2-TC;

-- text convention ------------------------------------------------------------------------     

	-------------------------------------------------------------------------------
	-- This data type is used to model textual information taken
	-- from the NVT ASCII character set.  By convention, objects
	-- with this syntax are declared as having
	--      SIZE (0..1023)
	-------------------------------------------------------------------------------
	DellString ::= DisplayString (SIZE (0..1023))

	DellRacType ::= INTEGER
	{
		other(1),               -- the DRAC type is not one of the following
		unknown(2),             -- the DRAC type is unknown
		dracIII(3),             -- Drac III
		era(4),                 -- ERA
		drac4(5),               -- Drac 4
		drac5(6),               -- Drac 5
		drac5MC(7),             -- Drac 5/MC
		cmc(8),                 -- CMC
		idrac(9)                -- iDRAC
	}

	DellStatus ::= INTEGER
	{
		other(1),               -- the status of the object is not one of the following:
		unknown(2),             -- the status of the object is unknown
										--  (not known or monitored)
		ok(3),                  -- the status of the object is ok
		nonCritical(4),         -- the status of the object is warning, non-critical
		critical(5),            -- the status of the object is critical (failure)
		nonRecoverable(6)       -- the status of the object is non-recoverable (dead)
	}

	-------------------------------------------------------------------------------
	-- DellPowerReading is a string representation of a floating point value, 
	--   having exactly 3 digits of precision, and a maximum of 31 characters.
	--
	-- DellChassisPowerIndexRange defines the possible chassis power instances
	--   in this MIB.
	--
	-- DellCMCPSUIndexRange defines the possible CMC Power Supply Unit (PSU) 
	--   instances, per chassis power instance, in this MIB.
	--
	-- DellCMCPSUCapable is an enumeration of PSU presence and/or monitoring 
	--   capabilities.
	--
	-- DellTemperatureReading is an integer value, expressed in degrees Celsius.
	-------------------------------------------------------------------------------
	DellPowerReading ::= DisplayString (SIZE (0..32))

	DellCMCPowerIndexRange ::= INTEGER (1..1)

	DellCMCPSUIndexRange ::= INTEGER (1..6)

	DellCMCPSUCapable ::= INTEGER
	{
		absent(1),      -- power supply is not present
		none(2),        -- no power monitoring abilities
		basic(3)        -- basic power monitoring abilities
	}

	DellTemperatureReading ::= INTEGER

	-------------------------------------------------------------------------------
	-- DellTimestamp is defined in the displayable format:
	--
	--			yyyymmddHHMMSS.uuuuuuDooo
	--
	-- where yyyy is the year, mm is the month number, dd is the day of the month,
	-- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the
	-- number of microseconds, D is the UTC offset direction, and ooo is the 
	-- offset from UTC, in minutes. 
	--
	-- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC.
	--
	-- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
	--   would be represented as: 19940525133015.000000-300
	-------------------------------------------------------------------------------
	DellTimestamp ::= DisplayString (SIZE (26))

	-------------------------------------------------------------------------------
	-- DellCMCServerIndexRange defines the possible chassis server instances
	--   in this MIB.
	--
	-- DellCMCServerCapable is an enumeration of server presence and/or monitoring 
	--   capabilities.
	-------------------------------------------------------------------------------
	DellCMCServerIndexRange ::= INTEGER (1..32)

	DellCMCServerCapable ::= INTEGER
	{
		absent(1),      -- server is not present
		none(2),        -- no server monitoring abilities
		basic(3),       -- basic server monitoring abilities
		off(4)          -- server is powered off
	}


-- MIB Objects and Tables --------------------------------------------------------

	dell                          OBJECT IDENTIFIER ::= { enterprises    674   }
	server3                       OBJECT IDENTIFIER ::= { dell           10892 }
	drsOutofBandGroup             OBJECT IDENTIFIER ::= { server3        2     }
	drsInformationGroup           OBJECT IDENTIFIER ::= { drsOutofBandGroup     1 }
	drsProductInfoGroup           OBJECT IDENTIFIER ::= { drsInformationGroup   1 }
	drsFirmwareGroup              OBJECT IDENTIFIER ::= { drsInformationGroup   2 }

	drsStatusGroup                OBJECT IDENTIFIER ::= { drsOutofBandGroup     2 }

	drsChassisStatusGroup         OBJECT IDENTIFIER ::= { drsOutofBandGroup     3 }
	drsStatusNowGroup             OBJECT IDENTIFIER ::= { drsChassisStatusGroup 1 }
	drsStatusPrevGroup            OBJECT IDENTIFIER ::= { drsChassisStatusGroup 2 }
	drsStatusChangeGroup          OBJECT IDENTIFIER ::= { drsChassisStatusGroup 3 }

	drsChassisPowerGroup          OBJECT IDENTIFIER ::= { drsOutofBandGroup     4 }

		DrsCMCPowerTableEntry ::= SEQUENCE
		{
			drsChassisIndex				DellCMCPowerIndexRange,
			drsPotentialPower				DellPowerReading,
			drsIdlePower					DellPowerReading,
			drsMaxPowerSpecification	DellPowerReading,
			drsPowerSurplus				DellPowerReading,
			drsKWhCumulative				DellPowerReading,
			drsKWhCumulativeTime			DellTimestamp,
			drsWattsPeakUsage				DellPowerReading,
			drsWattsPeakTime				DellTimestamp,
			drsWattsMinUsage				DellPowerReading,
			drsWattsMinTime				DellTimestamp,
			drsWattsResetTime				DellTimestamp,
			drsWattsReading				DellPowerReading,
			drsAmpsReading					DellPowerReading
		}

		DrsCMCPSUTableEntry ::= SEQUENCE
		{
			drsPSUChassisIndex			DellCMCPowerIndexRange,
			drsPSUIndex						DellCMCPSUIndexRange,
			drsPSULocation					DellString,
			drsPSUMonitoringCapable		DellCMCPSUCapable,
			drsPSUVoltsReading			DellPowerReading,
			drsPSUAmpsReading				DellPowerReading,
			drsPSUWattsReading			DellPowerReading
		}

	drsChassisServerGroup         OBJECT IDENTIFIER ::= { drsOutofBandGroup     5 }

		DrsCMCServerTableEntry ::= SEQUENCE
		{
			drsServerIndex					DellCMCServerIndexRange,
			drsServerMonitoringCapable DellCMCServerCapable,
			drsServerServiceTag			DellString,
			drsServerSlotName				DellString,
			drsServerSlotNumber			DellString
		}

	drsCMCAlertGroup              OBJECT IDENTIFIER ::= { drsOutofBandGroup    20 }
	drsChassisAlertVariables      OBJECT IDENTIFIER ::= { drsCMCAlertGroup     10 }
	drsChassisAlertGroup          OBJECT IDENTIFIER ::= { drsCMCAlertGroup   2000 }

	drsAlertGroup                 OBJECT IDENTIFIER ::= { drsOutofBandGroup  5000 }
	drsAlertVariables             OBJECT IDENTIFIER ::= { drsAlertGroup        10 }
        

-- Variables and Traps ------------------------------------------------------------------------

	-------------------------------------------------------------------------------
	-- group: product information
	-------------------------------------------------------------------------------

	drsProductName      OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0001 This attribute defines the product name of a chassis management controller." 
			::= { drsProductInfoGroup 1 }

	drsProductShortName OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0002 This attribute defines the short product name of a chassis management controller. " 
			::= { drsProductInfoGroup 2 }

	drsProductDescription OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0003 This attribute defines the product description of a chassis management controller. " 
			::= { drsProductInfoGroup 3 }

	drsProductManufacturer OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. " 
			::= { drsProductInfoGroup 4 }

	drsProductVersion OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0005 This attribute defines the product version of a chassis management controller. " 
			::= { drsProductInfoGroup 5 }

	drsChassisServiceTag OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0007 This attribute defines the Service Tag of the chassis. " 
			::= { drsProductInfoGroup 6 }

	drsProductURL       OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. "
			::= { drsProductInfoGroup 7 }
                        
	drsProductChassisAssetTag  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0008 This attribute defines the Asset Tag of the chassis. "
			::= { drsProductInfoGroup 8 }

	drsProductChassisLocation  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0009 This attribute defines the location of the chassis. "
			::= { drsProductInfoGroup 9 }

	drsProductChassisName  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0010 This attribute defines the name of the chassis. "
			::= { drsProductInfoGroup 10 }

	drsSystemServiceTag  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0011 This attribute defines the service tag of a system. "
			::= { drsProductInfoGroup 11 }

	drsProductSystemAssetTag  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0012 This attribute defines the asset tag of a system. "
			::= { drsProductInfoGroup 12 }

	drsProductSystemSlot OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0013 This attribute defines the slot number of a CMC. "
			::= { drsProductInfoGroup 13 }

	drsProductType  OBJECT-TYPE
		SYNTAX          DellRacType
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0014 This attribute defines type of a remote access card "
			::= { drsProductInfoGroup 14 }
               
	drsProductChassisDataCenter  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0015 This attribute defines the Data Center locator of the chassis. "
			::= { drsProductInfoGroup 15 }

	drsProductChassisAisle  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0016 This attribute defines the Aisle locator of the chassis. "
			::= { drsProductInfoGroup 16 }

	drsProductChassisRack  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0017 This attribute defines the Rack locator of the chassis. "
			::= { drsProductInfoGroup 17 }

	drsProductChassisRackSlot  OBJECT-TYPE
		SYNTAX          DellString 
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. "
			::= { drsProductInfoGroup 18 }

	drsFirmwareVersion  OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0002.0001 This attribute defines the firmware version of a chassis management controller. " 
			::= { drsFirmwareGroup 1 }

	drsiKVMFirmwareVersion  OBJECT-TYPE
		SYNTAX          DellString
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0001.0002.0002 This attribute defines the firmware version of the iKVM. " 
			::= { drsFirmwareGroup 2 }

	-------------------------------------------------------------------------------
	-- group: chassis status
	-------------------------------------------------------------------------------

	drsGlobalSystemStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0002.0001.0001 This attribute defines the overall chassis status
                      being monitored by the chassis management card." 
			::= { drsStatusGroup 1 }

	drsGlobalCurrStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0001 This attribute defines the overall chassis status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 1 }

	drsIOMCurrStatus  OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0002 This attribute defines the IOM subsystem status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 2 }

	drsKVMCurrStatus  OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0003 This attribute defines the iKVM subsystem health status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 3 }

	drsRedCurrStatus  OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0004 This attribute defines the Redundancy status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 4 }

	drsPowerCurrStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0005 This attribute defines the power subsystem health status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 5 }

	drsFanCurrStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0006 This attribute defines the Fan subsystem health status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 6 }

	drsBladeCurrStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0007 This attribute defines the Blade subsystem health status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 7 }

	drsTempCurrStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0008 This attribute defines the Temp Sensor subsystem health status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 8 }

	drsCMCCurrStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0009 This attribute defines the CMC health status
                      being monitored by the chassis management card." 
			::= { drsStatusNowGroup 9 }

	drsChassisFrontPanelAmbientTemperature OBJECT-TYPE
		SYNTAX          DellTemperatureReading
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0010 This attribute defines the ambient temperature
                      reading (in degrees Celsius) for the chassis front panel controller." 
			::= { drsStatusNowGroup 10 }

	drsCMCAmbientTemperature OBJECT-TYPE
		SYNTAX          DellTemperatureReading
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0011 This attribute defines the ambient temperature
                      reading (in degrees Celsius) for the chassis management card." 
			::= { drsStatusNowGroup 11 }

	drsCMCProcessorTemperature OBJECT-TYPE
		SYNTAX          DellTemperatureReading
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0012 This attribute defines the temperature reading
                      (in degrees Celsius) for the chassis management card processor." 
			::= { drsStatusNowGroup 12 }

	drsGlobalPrevStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0002.0001 This attribute defines the previous chassis status
                      recorded by the chassis management card." 
			::= { drsStatusPrevGroup 1 }
                
	drsIOMPrevStatus    OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0002.0002 This attribute defines the previous IOM subsystem status
                      recorded by the chassis management card." 
			::= { drsStatusPrevGroup 2 }

	drsKVMPrevStatus    OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0002.0003 This attribute defines the previous iKVM subsystem health status
                      recorded by the chassis management card." 
			::= { drsStatusPrevGroup 3 }

	drsRedPrevStatus    OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0002.0004 This attribute defines the previous Redundancy status
                      recorded by the chassis management card." 
			::= { drsStatusPrevGroup 4 }

	drsPowerPrevStatus  OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0002.0005 This attribute defines the previous power subsystem health status
                      recorded by the chassis management card." 
			::= { drsStatusPrevGroup 5 }

	drsFanPrevStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0002.0006 This attribute defines the previous Fan health status
                      being monitored by the chassis management card." 
			::= { drsStatusPrevGroup 6 }

	drsBladePrevStatus  OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0002.0007 This attribute defines the previous Blade subsystem health status
                      recorded by the chassis management card." 
			::= { drsStatusPrevGroup 7 }

	drsTempPrevStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0008 This attribute defines the Temp Sensor health status
                      being monitored by the chassis management card." 
			::= { drsStatusPrevGroup 8 }

	drsCMCPrevStatus OBJECT-TYPE
		SYNTAX          DellStatus
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0001.0009 This attribute defines the CMC health status
                      being monitored by the chassis management card." 
			::= { drsStatusPrevGroup 9 }

	drsGlobalChangeTime OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0001 This attribute defines the timestamp of the most recent 
                      global status change." 
			::= { drsStatusChangeGroup 1 }

	drsIOMChangeTime    OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0002 This attribute defines the timestamp of the most recent 
                      IOM status change." 
			::= { drsStatusChangeGroup 2 }

	drsKVMChangeTime    OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0003 This attribute defines the timestamp of the most recent 
                      iKVM status change." 
			::= { drsStatusChangeGroup 3 }

	drsRedChangeTime    OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0004 This attribute defines the timestamp of the most recent 
                      Redundancy status change." 
			::= { drsStatusChangeGroup 4 }

	drsPowerChangeTime  OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0005 This attribute defines the timestamp of the most recent 
                      power health status change." 
			::= { drsStatusChangeGroup 5 }

	drsFanChangeTime OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0006 This attribute defines the timestamp of the most recent 
                      Fan health status change." 
			::= { drsStatusChangeGroup 6 }

	drsBladeChangeTime  OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0007 This attribute defines the timestamp of the most recent 
                      Blade health status change." 
			::= { drsStatusChangeGroup 7 }

	drsTempChangeTime OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0008 This attribute defines the timestamp of the most recent 
                      Temp Sensor health status change." 
			::= { drsStatusChangeGroup 8 }

	drsCMCChangeTime OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION     "0003.0003.0009 This attribute defines the timestamp of the most recent 
                      CMC health status change." 
			::= { drsStatusChangeGroup 9 }

	-------------------------------------------------------------------------------
	-- group: chassis power
	-------------------------------------------------------------------------------

	drsCMCPowerTable OBJECT-TYPE
		SYNTAX			SEQUENCE OF DrsCMCPowerTableEntry
		ACCESS			not-accessible
		STATUS			mandatory
		DESCRIPTION		"0004.0001 This object defines the CMC power table."
			::= { drsChassisPowerGroup 1 }

	drsCMCPowerTableEntry OBJECT-TYPE
		SYNTAX			DrsCMCPowerTableEntry
		ACCESS      	not-accessible
		STATUS      	mandatory
		DESCRIPTION 	"0004.0001.0001 This object defines the CMC power table entry."
		INDEX       	{ drsChassisIndex }
			::= { drsCMCPowerTable 1 }

	drsCMCPSUTable OBJECT-TYPE
		SYNTAX			SEQUENCE OF DrsCMCPSUTableEntry
		ACCESS			not-accessible
		STATUS			mandatory
		DESCRIPTION		"0004.0002 This object defines the CMC PSU table."
			::= { drsChassisPowerGroup 2 }

	drsCMCPSUTableEntry OBJECT-TYPE
		SYNTAX			DrsCMCPSUTableEntry
		ACCESS      	not-accessible
		STATUS      	mandatory
		DESCRIPTION 	"0004.0002.0001 This object defines the CMC PSU table entry."
		INDEX       	{ drsPSUChassisIndex, drsPSUIndex }
			::= { drsCMCPSUTable 1 }

	-------------------------------------------------------------------------------
	-- table: CMC power information
	-------------------------------------------------------------------------------

	drsChassisIndex OBJECT-TYPE
		SYNTAX			DellCMCPowerIndexRange
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0001 This attribute defines the index
							(one-based) of the associated chassis."
			::= { drsCMCPowerTableEntry 1 }

	drsPotentialPower OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0002 This attribute defines the power (in Watts) required by
							the chassis infrastructure, plus the sum of the maximum power requirements
							for all currently powered-on servers."
			::= { drsCMCPowerTableEntry 2 }

	drsIdlePower OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0003 This attribute defines the power (in Watts) required by 
							the chassis	infrastructure, plus the sum of the minimum power requirements
							for all currently powered-on servers."
			::= { drsCMCPowerTableEntry 3 }

	drsMaxPowerSpecification OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0004 This attribute defines the power limit (in Watts) 
							at which server throttling will take place."
			::= { drsCMCPowerTableEntry 4 }


	drsPowerSurplus OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0005 This attribute defines the power surplus (in Watts)
							remaining above the drsPotentialPower reading." 
			::= { drsCMCPowerTableEntry 5 }

	drsKWhCumulative OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0006 This attribute defines the cumulative chassis power
							usage (in KWh) since last reset." 
			::= { drsCMCPowerTableEntry 6 }

	drsKWhCumulativeTime OBJECT-TYPE
		SYNTAX			DellTimestamp
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0007 This attribute defines the timestamp of the most recent
							chassis power accumulator reset." 
			::= { drsCMCPowerTableEntry 7 }

	drsWattsPeakUsage OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0008 This attribute defines the chassis peak power
							usage (in Watts) since last reset." 
			::= { drsCMCPowerTableEntry 8 }

	drsWattsPeakTime OBJECT-TYPE
		SYNTAX			DellTimestamp
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0009 This attribute defines the timestamp of the most recent
							chassis peak power usage." 
			::= { drsCMCPowerTableEntry 9 }

	drsWattsMinUsage OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0010 This attribute defines the chassis mimimum power
							usage (in Watts) since last reset." 
			::= { drsCMCPowerTableEntry 10 }

	drsWattsMinTime OBJECT-TYPE
		SYNTAX			DellTimestamp
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0011 This attribute defines the timestamp of the most recent
							chassis minimum power usage." 
			::= { drsCMCPowerTableEntry 11 }

	drsWattsResetTime OBJECT-TYPE
		SYNTAX			DellTimestamp
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0012 This attribute defines the timestamp of the most recent
							reset of the chassis min/peak Watts readings." 
			::= { drsCMCPowerTableEntry 12 }

	drsWattsReading OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0013 This attribute defines the instantaneous chassis power
							usage (in Watts)." 
			::= { drsCMCPowerTableEntry 13 }

	drsAmpsReading OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0001.0001.0014 This attribute defines the instantaneous chassis current
							usage (in Watts)." 
			::= { drsCMCPowerTableEntry 14 }

	-------------------------------------------------------------------------------
	-- table: CMC PSU info
	-------------------------------------------------------------------------------

	drsPSUChassisIndex OBJECT-TYPE
		SYNTAX			DellCMCPowerIndexRange
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0002.0001.0001 This attribute defines the index
							(one-based) of the associated chassis."
			::= { drsCMCPSUTableEntry 1 }

	drsPSUIndex OBJECT-TYPE
		SYNTAX			DellCMCPSUIndexRange
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0002.0001.0002 This attribute defines the index
							(one-based) of the associated CMC PSU."
			::= { drsCMCPSUTableEntry 2 }

	drsPSULocation OBJECT-TYPE
		SYNTAX			DellString
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0002.0001.0003 This attribute defines the location
							of the CMC PSU."
			::= { drsCMCPSUTableEntry 3 }

	drsPSUMonitoringCapable OBJECT-TYPE
		SYNTAX			DellCMCPSUCapable
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0002.0001.0004 This attribute defines the PSU Monitoring
							capabilities, or the absence of a PSU in this location."
			::= { drsCMCPSUTableEntry 4 }

	drsPSUVoltsReading OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0002.0001.0005 This attribute defines the instantaneous
							PSU Voltage reading."
			::= { drsCMCPSUTableEntry 5 }

	drsPSUAmpsReading OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0002.0001.0006 This attribute defines the instantaneous
							PSU Current reading."
			::= { drsCMCPSUTableEntry 6 }

	drsPSUWattsReading OBJECT-TYPE
		SYNTAX			DellPowerReading
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0004.0002.0001.0007 This attribute defines the instantaneous
							PSU Wattage reading."
			::= { drsCMCPSUTableEntry 7 }

	-------------------------------------------------------------------------------
	-- group: chassis servers
	-------------------------------------------------------------------------------

	drsCMCServerTable OBJECT-TYPE
		SYNTAX			SEQUENCE OF DrsCMCServerTableEntry
		ACCESS			not-accessible
		STATUS			mandatory
		DESCRIPTION		"0005.0001 This object defines the CMC server table."
			::= { drsChassisServerGroup 1 }

	drsCMCServerTableEntry OBJECT-TYPE
		SYNTAX			DrsCMCServerTableEntry
		ACCESS      	not-accessible
		STATUS      	mandatory
		DESCRIPTION 	"0005.0001.0001 This object defines the CMC server table entry."
		INDEX       	{ drsServerIndex }
			::= { drsCMCServerTable 1 }

	-------------------------------------------------------------------------------
	-- table: CMC Server info
	-------------------------------------------------------------------------------

	drsServerIndex OBJECT-TYPE
		SYNTAX			DellCMCServerIndexRange
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0005.0001.0001.0001 This attribute defines the index
							(one-based) of the associated CMC server."
			::= { drsCMCServerTableEntry 1 }

	drsServerMonitoringCapable OBJECT-TYPE
		SYNTAX			DellCMCServerCapable
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0005.0001.0001.0002 This attribute defines the server monitoring
							capabilities, or the absence of a server in this location."
			::= { drsCMCServerTableEntry 2 }

	drsServerServiceTag OBJECT-TYPE
		SYNTAX			DellString
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0005.0001.0001.0003 This attribute defines the Service Tag
							of the CMC server."
			::= { drsCMCServerTableEntry 3 }

	drsServerSlotName OBJECT-TYPE
		SYNTAX			DellString
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0005.0001.0001.0004 This attribute defines the Slot Name
							of the CMC server."
			::= { drsCMCServerTableEntry 4 }

	drsServerSlotNumber OBJECT-TYPE
		SYNTAX			DellString
		ACCESS			read-only
		STATUS			mandatory
		DESCRIPTION		"0005.0001.0001.0005 This attribute defines the Chassis
							Slot Number of the CMC server."
			::= { drsCMCServerTableEntry 5 }

	-------------------------------------------------------------------------------
	-- group: chassis alerts
	-------------------------------------------------------------------------------

            drsCASubSystem      OBJECT-TYPE
                SYNTAX		  DellString
                ACCESS		  read-only
                STATUS		  mandatory
                DESCRIPTION     "0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert"
               ::= { drsChassisAlertVariables 1 }

            drsCASSCurrStatus   OBJECT-TYPE
                SYNTAX		  DellStatus
                ACCESS		  read-only
                STATUS		  mandatory
                DESCRIPTION     "0020.0010.0002 This attribute defines the Current Status of the Alerting 
                                 Sub-System"
               ::= { drsChassisAlertVariables 2 }

            drsCASSPrevStatus   OBJECT-TYPE
                SYNTAX		  DellStatus
                ACCESS		  read-only
                STATUS		  mandatory
                DESCRIPTION     "0020.0010.0003 This attribute defines the Previous Status of the Alerting 
                                 Sub-System"
               ::= { drsChassisAlertVariables 3 }

            drsCASSChangeTime   OBJECT-TYPE
                SYNTAX		  TimeTicks
                ACCESS		  read-only
                STATUS		  mandatory
                DESCRIPTION     "0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of 
                                 the Alerting Sub-System"
               ::= { drsChassisAlertVariables 4 }

            drsCAMessage        OBJECT-TYPE
                SYNTAX		  DellString
                ACCESS		  read-only
                STATUS		  mandatory
                DESCRIPTION     "0020.0010.0005 This attribute defines the CSSD message of the CMC Alert"
               ::= { drsChassisAlertVariables 5 }

            alertCMCTestTrap  TRAP-TYPE
                ENTERPRISE 	  drsOutofBandGroup
                DESCRIPTION   "The CMC has generated a test trap"
                --#TYPE "CMC Test Trap"
                --#SUMMARY "CMC Test Trap"
                --#SEVERITY INFORMATIONAL
                --#CATEGORY Error Events
               ::= 2000
              
            alertCMCNormalTrap  TRAP-TYPE
                ENTERPRISE  	  drsOutofBandGroup
                VARIABLES { 	  drsProductChassisName,
                                drsProductChassisLocation,
                                drsGlobalCurrStatus,
                                drsCASubSystem,
                                drsCASSCurrStatus,
                                drsCASSPrevStatus,
                                drsCASSChangeTime,
                                drsCAMessage }
                DESCRIPTION     "The CMC reported a return-to-normal or informational event."
                --#TYPE "CMC Return-to-Normal / Informational Trap"
                --#SUMMARY "Return-to-Normal / Informational Trap from CMC in system %s in location %s, message: %s"
                --#ARGUMENTS {0,1,7}
                --#SEVERITY NORMAL
                --#CATEGORY Error Events
               ::= 2002

            alertCMCWarningTrap TRAP-TYPE
                ENTERPRISE 	    drsOutofBandGroup
                VARIABLES {     drsProductChassisName,
                                drsProductChassisLocation,
                                drsGlobalCurrStatus,
                                drsCASubSystem,
                                drsCASSCurrStatus,
                                drsCASSPrevStatus,
                                drsCASSChangeTime,
                                drsCAMessage }
                DESCRIPTION     "The CMC reported a warning event."
                --#TYPE "CMC Warning Trap"
                --#SUMMARY "Warning Trap from CMC in system %s in location %s, message: %s"
                --#ARGUMENTS {0,1,7}
                --#SEVERITY WARNING
                --#CATEGORY Error Events
               ::= 2003

            alertCMCCriticalTrap TRAP-TYPE
                ENTERPRISE 	    drsOutofBandGroup
                VARIABLES { 	  drsProductChassisName,
                                drsProductChassisLocation,
                                drsGlobalCurrStatus,
                                drsCASubSystem,
                                drsCASSCurrStatus,
                                drsCASSPrevStatus,
                                drsCASSChangeTime,
                                drsCAMessage }
                DESCRIPTION     "The CMC reported a critical event."
                --#TYPE "CMC Critical Trap"
                --#SUMMARY "Critical Trap from CMC in system %s in location %s, message: %s"
                --#ARGUMENTS {0,1,7}
                --#SEVERITY CRITICAL
                --#CATEGORY Error Events
               ::= 2004

            alertCMCNonRecoverableTrap TRAP-TYPE
                ENTERPRISE 	    drsOutofBandGroup
                VARIABLES { 	  drsProductChassisName,
                                drsProductChassisLocation,
                                drsGlobalCurrStatus,
                                drsCASubSystem,
                                drsCASSCurrStatus,
                                drsCASSPrevStatus,
                                drsCASSChangeTime,
                                drsCAMessage }
                DESCRIPTION     "The CMC reported a catastrophic event."
                --#TYPE "CMC Non-Recoverable Trap"
                --#SUMMARY "Non-Recoverable Trap from CMC in system %s in location %s, message: %s"
                --#ARGUMENTS {0,1,7}
                --#SEVERITY NON-RECOVERABLE
                --#CATEGORY Error Events
               ::= 2005
               
    --
    -- Legacy Alerting
    --

        drsAlertSystem         OBJECT-TYPE
            SYNTAX             OCTET STRING (SIZE (0..255))
            ACCESS             read-only
            STATUS             mandatory
            DESCRIPTION
            "5000.0010.0001 Name of the system generating the alert."
            --DEFAULT get-function-async    get_%n_async
            --DEFAULT next-function-async   std_next_async
            ::= { drsAlertVariables 1 }

        drsAlertTableIndexOID  OBJECT-TYPE
            SYNTAX             OBJECT IDENTIFIER
            ACCESS             read-only
            STATUS             mandatory
            DESCRIPTION
            "5000.0010.0002 0.0"
            --DEFAULT get-function-async    get_OID_null_async
            --DEFAULT next-function-async   std_next_async
            ::= { drsAlertVariables 2 }

        drsAlertMessage        OBJECT-TYPE
            SYNTAX             OCTET STRING (SIZE (0..1024))
            ACCESS             read-only
            STATUS             mandatory
            DESCRIPTION
            "5000.0010.0003 Message describing the alert."
            --DEFAULT get-function-async    get_string_null_async
            --DEFAULT next-function-async   std_next_async
            ::= { drsAlertVariables 3 }

        drsAlertCurrentStatus  OBJECT-TYPE
            SYNTAX             DellStatus
            ACCESS             read-only
            STATUS             mandatory
            DESCRIPTION
            "5000.0010.0004 Current status of object causing the alert."
            --DEFAULT get-function-async    get_dellstatus_unknow_async
            --DEFAULT next-function-async   std_next_async
            ::= { drsAlertVariables 4 }

        drsAlertPreviousStatus OBJECT-TYPE
            SYNTAX             DellStatus
            ACCESS             read-only
            STATUS             mandatory
            DESCRIPTION
            "5000.0010.0005 Previous status of object causing the alert."
            --DEFAULT get-function-async    get_dellstatus_unknow_async
            --DEFAULT next-function-async   std_next_async
            ::= { drsAlertVariables 5 }

        drsAlertData           OBJECT-TYPE
            SYNTAX             OCTET STRING (SIZE (0..1024))
            ACCESS             read-only
            STATUS             mandatory
            DESCRIPTION
            "5000.0010.0006 Alert data."
            --DEFAULT get-function-async    get_string_null_async
            --DEFAULT next-function-async   std_next_async
            ::= { drsAlertVariables 6 }

        alertDrscTestTrapEvent      TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC generated a test trap event in response to a user request."
        --#TYPE "Dell RAC Test TRAP Event"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY INFORMATIONAL
        --#CATEGORY Status Events
        ::= 1001
    
        alertDrscAuthError          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC Authentication Failures during a time period have Exceeded a Threshold."
        --#TYPE "Dell RAC Authentication Error"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MINOR
        --#CATEGORY Error Events
        ::= 1002

        alertDrscLostESM          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC cannot communicate with the baseboard management controller (ESM)."
        --#TYPE "Dell RAC Lost Communication with ESM"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MINOR
        --#CATEGORY Error Events
        ::= 1003

        alertDrscFoundESM          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC is communicating normally with the baseboard management controller (ESM)."
        --#TYPE "Dell RAC Communication with ESM is OK"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY INFORMATIONAL
        --#CATEGORY Error Events
        ::= 1004

        alertDrscPowerOff          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected a System power state change to powered-off."
        --#TYPE "Dell RAC Detected System Powered-Off"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY CRITICAL
        --#CATEGORY Error Events
        ::= 1005

        alertDrscPowerOn          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected a system power state change to powered-on."
        --#TYPE "Dell RAC Detected System Powered-On"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY INFORMATIONAL
        --#CATEGORY Error Events
        ::= 1006

        alertDrscWatchdogExpired          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected that the system watchdog has expired indicating a system hang."
        --#TYPE "Dell RAC Detected Watchdog Expired"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY CRITICAL
        --#CATEGORY Error Events
        ::= 1007

        alertDrscBattLow          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes."
        --#TYPE "Dell RAC Battery Charge Low"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MINOR
        --#CATEGORY Error Events
        ::= 1008

        alertDrscTempNormal          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC Temperature probe has retured to a normal value."
        --#TYPE "Dell RAC Temperature Normal"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY INFORMATIONAL
        --#CATEGORY Error Events
        ::= 1009

        alertDrscTempWarning          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC Temperature probe has detected a Warning value."
        --#TYPE "Dell RAC Temperature Warning"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MINOR
        --#CATEGORY Error Events
        ::= 1010

        alertDrscTempCritical          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC Temperature probe has detected a failure (or critical) value."
        --#TYPE "Dell RAC Temperature Failure"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY CRITICAL
        --#CATEGORY Error Events
        ::= 1011

        alertDrscVoltNormal          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC voltage has returned to a normal value."
        --#TYPE "Dell RAC Voltage Normal"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY INFORMATIONAL
        --#CATEGORY Error Events
        ::= 1012

        alertDrscVoltWarning          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC voltage probe has detected a warning value."
        --#TYPE "Dell RAC Battery Warning"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MINOR
        --#CATEGORY Error Events
        ::= 1013

        alertDrscVoltCritical          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC voltage probe has detected a failure (or critical) value."
        --#TYPE "Dell RAC Voltage Failure"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY CRITICAL
        --#CATEGORY Error Events
        ::= 1014

        alertDrscSELWarning          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected a new event in the System Event Log with Severity: Warning."
        --#TYPE "Dell RAC System Event Log Warning"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MAJOR
        --#CATEGORY Error Events
        ::= 1015

        alertDrscSELCritical          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected a new event in the System Event Log with Severity: Critical."
        --#TYPE "Dell RAC System Event Log Critical"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY CRITICAL
        --#CATEGORY Error Events
        ::= 1016

        alertDrscSEL80percentFull          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected that the System Event Log is 80% full."
        --#TYPE "Dell System Event Log 80% Full Warning"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MAJOR
        --#CATEGORY Status Events
        ::= 1017

        alertDrscSEL90percentFull          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected that the System Event Log is 90% full."
        --#TYPE " Dell System Event Log 90% Full Warning "
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MAJOR
        --#CATEGORY Status Events
        ::= 1018

        alertDrscSEL100percentFull          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected that the System Event Log is 100% full."
        --#TYPE " Dell System Event Log 100% Full Warning "
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY MAJOR
        --#CATEGORY Status Events
        ::= 1019

        alertDrscSELNormal          TRAP-TYPE
        ENTERPRISE  drsOutofBandGroup
        VARIABLES { drsAlertSystem,
                    drsAlertTableIndexOID,
                    drsAlertMessage,
                    drsAlertCurrentStatus,
                    drsAlertPreviousStatus,
                    drsAlertData }
        DESCRIPTION
        "The RAC has detected a new event in the System Event Log with Severity: Normal."
        --#TYPE "Dell RAC System Event Log Normal"
        --#SUMMARY "%s"
        --#ARGUMENTS {2}
        --#SEVERITY INFORMATIONAL
        --#CATEGORY Error Events
        ::= 1020
END  